						Very Early Smoke Detection Apparatu
High-sensitivity air intake sensing
					
| VESDA Laser Compact (VLC-505) | |||
|---|---|---|---|
| Type approval 11-15 (Analog type, 1 air intake input, air pipe maximum length 50m) | |||
| Ambient  temperature  | 
						0 ~ 39℃ | color | Gray | 
| Relative humidity | 0 to 95% | Size | 225(W) X 225(H) X 85(D)mm | 
| Rated voltage | DC 24V | IP rating | 30 | 
| Current consumption | Monitoring 225mA / Alarm 245mA | Weight | 1.9kg | 
| Detection method | A method of measuring the scattering of light in a laser chamber by sucking smoke particles through an air intake pipe | Accessory material | VSP-005 (Filter) / VSP-515 (Terminaion Card) / VSP-501 (Aspirator) | 
| Sensitivity range | 0.005 to 20% obs/m | Threshold  Setting Range  | 
						
							Bounding 0.005% ~ 1.990% obs / m Execution 0.010% ~ 1.995% obs / m Fire 0.015% ~ 20.00% obs / m  | 
					
※ The VLC-505 / Laser Compact detector can install one air intake pipe and LED lamp on the front side to visually check the fire phase, normal or error status.
Real-time measurement of "current smoke concentration in the air" using a pipe network "Active" early detection of signs of fire Early detection of smoke.
				
				
				


| Comparing VESDA and existing fire detectors | |||
|---|---|---|---|
| Division | Existing fire detector | ![]()  | 
					|
| General detector | Analog detector | ||
| Sensitivity (%/m) | 4 to 10 (% / m) | 3 to 8 (% / m) | 0.005 (% / m) | 
| Fine smoke detection | X | X | X | 
| Alarm classification | Simple alarm | Multi-level (2) Alarm | Multi-level (3 ~ 4) Alarm | 
| Data Management | No function | No function Data storage Data storage, transmission | Data storage, transmission | 
| Environmental conditions (high / low temperature) | Influence | Influence | Influence Influence Influence Influence | 
| Equipment life | 5 to 10 years | 5 to 10 years | More than 10 years | 
| Fire Alarm Point | General Location: Fire Progress Stage | General Places: Fire Progress Stage | General Places: Early Stage of Fire | 
| Air-conditioning system: Fire spreading stage | Air-conditioning system: Fire spreading stage | Air-conditioning system: Early stage of fire | |
| Maintenance | 5 ~ 10 years | Failure check failure | Failure Self diagnosis | 
| Automatic environment calibration technology | X | X | Notify operator of dust, humidity, air flow, etc. | 
| Adjust sensitivity depending on environment | X | X | Adjustment of random sensitivity according to the application place of clean room, factory, etc. | 
| Adjust sensitivity depending on environment | X | X | Sensitivity can be set according to day / night environment |